Conica Enterprises
 
You are here: Home Product Gallery AUTOCLAVES STEAM STERILIZERS HOSPITAL VERTICAL HIGH PRESSURE AUTOCLAVE (MICROPROCESSOR)
PDFPrintE-mail


HOSPITAL VERTICAL HIGH PRESSURE AUTOCLAVE (MICROPROCESSOR)
View Full-Size Image


HOSPITAL VERTICAL HIGH PRESSURE AUTOCLAVE (MICROPROCESSOR)

Price: Call for Pricing

Ask a question about this product

HOSPITAL VERTICAL HIGH PRESSURE STEAM STERILIZER WITH CENTRAL-LOCKING AND MICRO PROCESSOR CONTROL  (Item code 1044)

A Modern Hospital- Use Vertical  high pressure steam sterilizer with Central Locking System. Lid of diameter 12”and 16”, manufactured by Conica Enterprises.

CONICA vertical sterilizer made out of total medical grade stainless steel (16Gage) and top lid is Die pressed  thick solid S.S. plate. And polished for the elegant appearance.. Equipped with steam release valve and drain cock. Specially designed heat resistant gasket. New type of element of 3Kw is covered by removable cover to protect against electric shock. Spring-loaded SAFETY VALVE is provided for steam exhaust as an extra safety means in addition to the presence of an electric pressure-switch(microprocessor-based).

CONICA vertical sterilizer is equipped with automatic controls and safeguards to manage daily sterilization in the Hospital along with saving electricity.

CONICA vertical sterilizer is equipped with low water level cut off system. When water level falls down the equipment automatically cuts power supply to protect the elements from burning out dry. Also,in such circumstance, appropriate pilot lamp lights up and alarm is sounded to denote the paucity of water in side the Autoclave.

CONICA vertical sterilizer has thermal-control device (MICROPROCESSOR CONTROLLED) (digital temperature - pressure controller) incorporated. It economizes on power consumption since it cuts off the power supply to heaters when the pressure is achieved at 20psi and 126 degrees Celsius and re-energies the heating elements when pressure falls below the set point.

CONICA vertical sterilizer's front panel is provided with  pilot lamps to indicate the various phases of the sterilizing cycle and Alarm buzzer to denote of the completion of the sterilization cycle.

Provision has been made for digitally entering (feeding) a single custom programme characterised by custom settings of Temperature and Sterilisation Time into the ellectronic control system (microprocessor) of the device. These settings can be easily and simply altered by the operator at will according as  the type of load intended to be sterilized.

All phases of the cycle (MICROPROCESSOR CONTROLED) such as  steam generation process, auto air-purging phase, sterilization and  auto steam-exhaust  phase proceed automatically and can be easily MONITORED. At any time during the cycle the operator can appraise of the current (present) Temperature, the remaining sterilization or drying time, the successive phases and the water level  by means of the alphanumeric display. If any abnormal condition occurs, error massages are depicted via audible alarm as well as the alphanumeric display, thanks to the self-diagnostic function of the microprocessor software.

 The autoclave features an in built air-purging system controlled by the microprocessor which affords reasonably reliable air-purging for effective Air-Removal during the sterilization phase. Presence of air inside the sterilizing chamber during the sterilization phase is detrimental to the quality of sterilization because it hampers uniform distribution of steam and heat. Air is a poorer conductor of heat than steam and dry air has much less spore-killing power than steam.

 

  ITEM CODE NUMBER
PARAMETER 1044-A 1044-B 1044-C
CHAMBER SIZE (in mm) 300x500 400x600 450x750
CHAMBER CAPACITY
37 Litres 79 Litres
125 Litres
DOOR LOCKING SYSTEM
Radial
Radial Radial
LID LIFTING SYSTEM
Foot Lifting Foot Lifting
Foot Lifting
SAFETY VALVE SETTING
25 Psi
25 Psi 25 Psi
HIGH PRESSURE SAFETY
Micro Processor
Micro Processor Micro Processor
HIGH TEMPERATURE SAFETYCUT-OFF
Micro Processor Micro Processor Micro Processor
AIR PURGING
Micro Processor Micro Processor Micro Processor
STEAM EXHAUST
Micro ProcessorMicro Processor Micro Processor
STERILIZATION PRESSURE
20 Psi 20 Psi
20 Psi
STERILIZATION TEMPERATURE
126-Degree C
126 Degree C
126 Degree C
STERILIZATION TIMER
5-99 min
5-99 min 5-99 min
PRESSURE DISPLAY
Aneroid Type
Aneroid Type
Aneroid Type
TEMPERATURE DISPLAY
Digital Digital Digital
OVERHEAT AND CUT-OFF
Microprocessor Microprocessor Microprocessor
READY CYCLE (COMPLETION)
Microprocessor Microprocessor Microprocessor
LOW WATER LEVEL CUT-OFF Microprocessor Microprocessor Microprocessor
ELECTRICAL SUPPLY VOLTAGE
230V 230V 230V
POWER CONSUMPTION
3 KW 6 KW
9 KW

 





Customer Reviews:

matthews10  (Saturday, 11 May 2013)
Rating: 5
What to Look for in a Hard Drive That You Are Purchasing?rnWhen you are going to buy laptop hard drive, it is extremely important to look for one that
is going to be fast and large enough to accommodate all of your files and data needs. ItnYeah, it's just what I need, I'm about to have a new onenI
always use Dell Hard Disk Drives, what about you, guys?nGateway!!!lol


Login Form



Latest Events

No events
 
Name:*
Contact No:*
E-mail:*
Your Quiry:*